logo
Shenzhen Zhong Jian South Environment Co., Ltd.
Shenzhen Zhong Jian South Environment Co., Ltd.
Ürünler
Evde /

Ürünler

Upgrades Needed for Pharma‑Level Cleanroom

Ürün Ayrıntıları

Menşe yeri: Guangdong, Çin

Marka adı: ZJNF

Ödeme ve Nakliye Şartları

Min sipariş miktarı: 1

Fiyat: negotiate

Ambalaj bilgileri: kontrplak/ahşap paket

Teslim süresi: 18 gün

Ödeme koşulları: TT LC PayPal Kredi Kartı

En İyi Fiyatı Alın
Şimdi iletişime geçin
Özellikler
Vurgulamak:

pharma-level cleanroom upgrades

,

modular clean room solutions

,

cleanroom equipment with warranty

Uygulanabilir endüstriler:
İnşaat malzemeleri dükkanları, üretim tesisi, gıda ve içecek fabrikası, çiftlikler, restoran, ev kul
Çekirdek bileşenler:
Filtre
Yeterlik:
99%99,97% 0.3um
Yapı:
Panel filtresi
Gözeneklilik:
0.3u
boyut (l*w*h):
Özelleştirilmiş boyut
Öğe:
Pileli HEPA Filtre
Filtreleme Malzemesi:
cam lif/PP PET filtreleme ortamı
Çerçeve:
Galvanizli çelik/alüminyum
İç kaplama şeridi:
EVA/EPDM
Mastik:
Poliüretan
Ayırıcı:
Sıcak eriyik yapıştırıcı
Uygulanabilir endüstriler:
İnşaat malzemeleri dükkanları, üretim tesisi, gıda ve içecek fabrikası, çiftlikler, restoran, ev kul
Çekirdek bileşenler:
Filtre
Yeterlik:
99%99,97% 0.3um
Yapı:
Panel filtresi
Gözeneklilik:
0.3u
boyut (l*w*h):
Özelleştirilmiş boyut
Öğe:
Pileli HEPA Filtre
Filtreleme Malzemesi:
cam lif/PP PET filtreleme ortamı
Çerçeve:
Galvanizli çelik/alüminyum
İç kaplama şeridi:
EVA/EPDM
Mastik:
Poliüretan
Ayırıcı:
Sıcak eriyik yapıştırıcı
Açıklama
Upgrades Needed for Pharma‑Level Cleanroom

Upgrades Needed for Pharma‑Level Cleanroom

1. Air Handling & Filtration

  • More robust HVAC → You’d need higher air change rates:
    • ISO 7: ~60+ air changes per hour.
    • ISO 6: ~90–180 air changes per hour (lots of airflow!).
  • Additional HEPA (or ULPA) filters at terminal vents.
  • Strict laminar airflow → Smooth, unidirectional air flowing top‑to‑bottom or side‑to‑side, not random swirls.
  • Continuous pressure monitoring → Differential pressure gauges with active alarms if the cleanroom loses positive pressure.

2. Environmental Monitoring

  • Pharma environments require continuous monitoring of:
    • Particle counts (real‑time laser particle counters).
    • Microbial contamination (settle plates, surface swabs, air samplers).
    • Temperature and humidity.
  • All this data must be recorded and auditable. For mushrooms, you care about spores too, but you don’t log data to satisfy regulators.

3. Entry & Gowning Protocols

  • ISO 7–8 mushroom room: basic clean coveralls, gloves, hairnets = good.
  • Pharma ISO 6–7: multi‑stage gowning.
    • Separate entry airlocks (personnel and materials).
    • Garments: full sterile gowns, sterile gloves (double‑gloving), boot covers, sometimes masks and goggles/hoods.
  • Air showers at entry points are common.

4. Materials & Surfaces

  • Mushrooms: smooth, sealed, cleanable is fine.
  • Pharma: everything must be validated as non‑shedding, non‑porous, chemical‑resistant.
  • Often seamless epoxy flooring → no cracks allowed.
  • Corners are coved (rounded), not sharp, so nothing collects.

5. Cleaning & Validation Protocols

  • Mushrooms: regular sanitization with alcohol, bleach, peroxide fogging.
  • Pharma: cleaning must be validated and documented. Every cleaning agent has a written SOP (standard operating procedure). Staff are trained, checklists are signed, logs are kept… basically, mushrooms don’t care about paperwork, but regulators do.

6. Documentation & Compliance

  • Pharma = GMP (Good Manufacturing Practices).
    • Every procedure, from changing filters to mopping floors, has a written SOP.
    • Deviations must be written up and signed off.
    • Environmental monitoring results are archived.