logo
Shenzhen Zhong Jian South Environment Co., Ltd.
Shenzhen Zhong Jian South Environment Co., Ltd.
Ürünler
Evde /

Ürünler

ZJNF Class III Medical Device ‌Biosafety Cabinet (BSC) With 99.99 High Efficiency Hepa Air Filter

Ürün Ayrıntıları

Menşe yeri: Çin

Marka adı: ZJNF

Sertifika: CE

Model numarası: ZJNF-1

Ödeme ve Nakliye Şartları

Min sipariş miktarı: 1

Fiyat: negotiate

Ambalaj bilgileri: kontrplak/ahşap paket

Teslim süresi: 18 gün

Ödeme koşulları: tt lc PayPal kredi kartı

En İyi Fiyatı Alın
Şimdi iletişime geçin
Özellikler
Vurgulamak:

Class III medical biosafety cabinet

,

HEPA filter biosafety cabinet

,

laminar clean bench with warranty

Sunucu:
açıklık
Durum kodu:
403
Tanım:
Sunucu isteği anladı ancak yerine getirmeyi reddediyor.
Ürün adı:
403 Yasak
Sunucu:
açıklık
Durum kodu:
403
Tanım:
Sunucu isteği anladı ancak yerine getirmeyi reddediyor.
Ürün adı:
403 Yasak
Açıklama
ZJNF Class III Medical Device ‌Biosafety Cabinet (BSC) With 99.99 High Efficiency Hepa Air Filter

Biosafety Cabinet (BSC)
A biosafety cabinet is a critical laboratory equipment designed to protect operators, experimental samples, and the environment from hazardous biological agents. Classified as a Class III medical device, it utilizes a negative-pressure air purification system and HEPA filtration to prevent the spread of harmful microbial aerosols generated during experiments.

Core Functions

The biosafety cabinet provides ‌three layers of protection‌:

  1. Operator Protection‌: HEPA filters capture 99.99% of bacteria and viruses, preventing aerosol leakage.
  2. Sample Protection‌: A vertical laminar airflow barrier maintains sterility by blocking external contaminants.
  3. Environmental Protection‌: Negative pressure ensures unidirectional airflow, containing hazardous materials within the cabinet.

Operational Guidelines

  • Startup‌: Power on, activate lighting and fan, then raise the sash to the marked line after the indicator turns yellow.
  • Procedures‌: Minimize items inside to avoid disrupting airflow; move arms slowly and wait for airflow stabilization.
  • Prohibitions‌: Open flames (e.g., alcohol burners) are strictly prohibited—use infrared sterilizers instead.
  • Maintenance‌: Disinfect surfaces with 75% ethanol before/after use; replace filters regularly and monitor airflow velocity.

Key Difference from Laminar Flow Hood

Biosafety cabinets protect ‌personnel, samples, and the environment‌, while laminar flow hoods ‌only protect samples‌ (not operators). Therefore, biosafety cabinets are mandatory for handling infectious materials.